Technical Data Model 16I EMF Assembly

EMF DeviceSystem Parameters

Design Pressure 300 psig
Design Temperature 300 degrees F
Design Flow Rate 650 GPM
Flush Rate* 370 GPM process fluid
Flush Volume at Maximum Flush Flow 70 gallons (max)
Crud Retention (approximately) 7 lbs.
Ambient Temperature < 120 degrees F

*310 GPM is the minimum flow required to ensure positive cleaning action during back flush. There is no minimum required flow rate during the process filtering mode.

Plant Services Required

Power Supply 480 V AC, 3 phase, 60 Hz, 5 KVA
Air Supply 90 psig minimum/maximum
Cooling Water 5 GPM, 70-90 degrees F

Plant Interface

Space Requirements Skid assembly envelope 8’ x 8’ x 9’
Shipping Weight 12,500 lbs. (estimated)
Operating Weight 13,500 lbs. (estimated)
Skid Piping Connections 6” 300 lb. standard flanges for process piping
Electrical Connections Power input at Power Control Unit
Remote alarm output  
Plant Air Air manifold ‑ ¾” NPT (Air regulation by customer)

Codes and Standards

Filter Vessel ASME Boiler and Pressure Vessel Code, Section VIII, Div. 1
Valves ANSI B16.34
Piping ANSI B31.1
Electrical NEMA, current OSHA Standards and National Electric Code

Materials

Vessel

Shell - ASTM SA‑106, GR. B Carbon Steel or Equivalent
Heads - ASTM SA-234, GR WPB Carbon Steel or Equivalent
Nozzles - ASTM SA‑181, long neck flanges Carbon Steel or Equivalent

Piping ASTM A53, GR. B or ASTM A106 GR. B
Fittings ASTM A234, GR. WPB
Spheres TP 430 Ferritic Stainless Steel
Coil Cooler Tubing ASTM B75 Alloy 22 Copper